+ | [[Image:Nr3.png|50px|link=]]Fill in the fields.[[File:Fill in.png|thumb]][[Image:Nr4.png|50px|link=]]Click '''Register'''[[Image:Nr5 - Copy.png|50px|link=]]After registration, fill in login details in TeltoHeart mobile application to login. | ||
{| class="tlt-border" style="border: 1px solid #e8e8e8; background: white; width: 100%;" | {| class="tlt-border" style="border: 1px solid #e8e8e8; background: white; width: 100%;" | ||
|- | |- | ||
− | |colspan="3" style="text-align: center; background: white; padding: 10px;"| <p style="font-size:28px"><span style="color:#0054A6">'''How to Use TeltoHeart'''</span></p> | + | | colspan="3" style="text-align: center; background: white; padding: 10px;" |<p style="font-size:28px"><span style="color:#0054A6">'''How to Use TeltoHeart'''</span></p> |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr1.png|50px|link=]] To activate TeltoHeart, press and hold the button for not less than 10 seconds until the device screen powers on. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr1.png|50px|link=]] To activate TeltoHeart, press and hold the button for not less than 10 seconds until the device screen powers on. |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr2.png|50px|link=]] When TeltoHeart is turned on for the first time, it will prompt to download TeltoHeart application. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr2.png|50px|link=]] When TeltoHeart is turned on for the first time, it will prompt to download TeltoHeart application. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:TeltoHeart-welcome1.png|200px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr3.png|50px|link=]] You will be able to locate TeltoHeart on the TeltoHeart application as its name will be displayed on the TeltoHeart screen. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr3.png|50px|link=]] You will be able to locate TeltoHeart on the TeltoHeart application as its name will be displayed on the TeltoHeart screen. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:TeltoHeart-pair.png|200px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr4.png|50px|link=]] Visit <b>[https://teltonika-telemedic.com/products/teltoheart TeltoHeart]</b> to download the TeltoHeart application or scan the QR code below. Alternatively, you can explore the iOS app store or Google Play store and search for the TeltoHeart application made by Teltonika Telemedic. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr4.png|50px|link=]] Visit <b>[https://teltonika-telemedic.com/products/teltoheart TeltoHeart]</b> to download the TeltoHeart application or scan the QR code below. Alternatively, you can explore the iOS app store or Google Play store and search for the TeltoHeart application made by Teltonika Telemedic. |
|- | |- | ||
− | |style="text-align: left; | + | | colspan="3" style="text-align: left;" | |
{| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | {| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | ||
− | | style="width: 40px;height: 20px;padding: 10px;" | [[File:Note_icon.png|30 px|link=]] | + | | style="width: 40px;height: 20px;padding: 10px;" |[[File:Note_icon.png|30 px|link=]] |
− | || '''Please note:'''<br>Please be aware that if your mobile operating system is older than the version described in the guide, the app may not be visible. | + | ||'''Please note:'''<br>Please be aware that if your mobile operating system is older than the version described in the guide, the app may not be visible. |
|} | |} | ||
|- | |- | ||
− | | style="text-align: center; | + | | colspan="2" style="text-align: center;" |[[File:Scan_QR.png|border|class=tlt-border|200px|link=https://teltonika-telemedic.com/products/teltoheart]] |
|- | |- | ||
− | | style="text-align: center; | + | | colspan="1" style="text-align: center;" |[[File:Download_from_apple_store.png|180px|link=https://apps.apple.com/us/app/teltoheart/id1566566820]]<br />Scan the QR code to download the TeltoHeart application<br />from the Apple Store |
− | | style="text-align: center; | + | | colspan="2" style="text-align: center;" |<br><br>[[File:Download_from_googleplay.png|180px|link=https://play.google.com/store/apps/details?id=com.teltonika.telemedic.teltoheart]]<br />Scan the QR code to download the TeltoHeart application<br />from Google Play Store |
<br> | <br> | ||
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr5 - Copy.png|50px|link=]] After installing the app, tap [[Image:Myhealth-0.png|30px|link=]] icon to open the app. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr5 - Copy.png|50px|link=]] After installing the app, tap [[Image:Myhealth-0.png|30px|link=]] icon to open the app. |
|- | |- | ||
! colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''Registration'''</span></p> | ! colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''Registration'''</span></p> | ||
Line 110: | Line 111: | ||
| colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''First option'''</span></p> | | colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''First option'''</span></p> | ||
|- | |- | ||
− | | colspan="3" |[[Image:Nr1.png|50px|link=]] Visit https://teltocare.com | + | | colspan="3" |[[Image:Nr1.png|50px|link=]] Visit https://teltocare.com |
− | [[Image:Nr2.png|50px|link=]] Click '''Register''' | + | [[Image:Nr2.png|50px|link=]] Click '''Register''' |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
+ | [[File:Register.png|thumb]] | ||
+ | |- | ||
+ | |- | ||
+ | |- | ||
|- | |- | ||
| colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''Second option'''</span></p> | | colspan="3" |<p style="font-size:28px"><span style="color:#0054A6">'''Second option'''</span></p> | ||
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| If it is your first time using the app, sign-in by entering your email address and the password, which has been sent to your email. Tap Log in to proceed. | + | | colspan="3" style="text-align: left; padding: 10px;" |If it is your first time using the app, sign-in by entering your email address and the password, which has been sent to your email. Tap Log in to proceed. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[File:Group 4238.png|thumb]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr6.png|50px|link=]] TeltoHeart application will prompt you to change the default password to a personal preferred password of your choice. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr6.png|50px|link=]] TeltoHeart application will prompt you to change the default password to a personal preferred password of your choice. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:MyHealth-2.png|300px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr7.png|50px|link=]] Once you have successfully changed your password, the next step is to review and accept the Terms and Conditions. You will be prompted to acknowledge and agree to the Terms and Conditions and Privacy policy before proceeding. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr7.png|50px|link=]] Once you have successfully changed your password, the next step is to review and accept the Terms and Conditions. You will be prompted to acknowledge and agree to the Terms and Conditions and Privacy policy before proceeding. |
|- | |- | ||
− | |style="text-align: left; | + | | colspan="3" style="text-align: left;" |[[Image:Nr8.png|50px|link=]] Once signed-in, the TeltoHeart application will ask for Bluetooth permissions. Tap Allow to let the application use Bluetooth connection. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |<br><p style="font-size:28px"><span style="color:#0054A6">'''How to Pair TeltoHeart with TeltoHeart mobile application'''</span></p> |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr1.png|50px|link=]] Tap Pair device to proceed with the pairing process. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr1.png|50px|link=]] Tap Pair device to proceed with the pairing process. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:Group 4183.png|300px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr2.png|50px|link=]] TeltoHeart application will initiate a search for nearby devices. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr2.png|50px|link=]] TeltoHeart application will initiate a search for nearby devices. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:MyHealth-4.png|300px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr3.png|50px|link=]] Select your smart wearable by tapping on it. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr3.png|50px|link=]] Select your smart wearable by tapping on it. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:MyHealth-5.png|300px|link=]] |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| [[Image:Nr4.png|50px|link=]] TeltoHeart will notify you of an incoming pair request. | + | | colspan="3" style="text-align: left; padding: 10px;" |[[Image:Nr4.png|50px|link=]] TeltoHeart will notify you of an incoming pair request. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:TeltoHeart-paircode.png|200px|link=]] |
|- | |- | ||
− | |style="text-align: left; | + | | colspan="3" style="text-align: left;" |[[Image:Nr5 - Copy.png|50px|link=]] When prompted to do so, enter the passkey shown on your TeltoHeart into the Bluetooth pairing request window in the TeltoHeart application. |
|- | |- | ||
− | |style="text-align: left; | + | | colspan="3" style="text-align: left;" |[[Image:Nr6.png|50px|link=]] TeltoHeart will notify you about a successful pair with the TeltoHeart application. |
|- | |- | ||
− | |style="text-align: center; | + | | colspan="3" style="text-align: center;" |[[Image:TeltoHeart-paired.png|200px|link=]] |
|- | |- | ||
− | |style="text-align: left; | + | | colspan="3" style="text-align: left;" |[[Image:Nr7.png|50px|link=]] Make sure TeltoHeart application is always running in the background, otherwise the data transfer will not be available. |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| | + | | colspan="3" style="text-align: left; padding: 10px;" | |
{| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | {| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | ||
− | | style="width: 40px;height: 20px;padding: 10px;" | [[File:Note_icon.png|30 px|link=]] | + | | style="width: 40px;height: 20px;padding: 10px;" |[[File:Note_icon.png|30 px|link=]] |
− | || '''Please note:'''<br>To ensure uninterrupted data transfer from your watch to the platform, it is important to keep the TeltoHeart application running in the background at all times. If you close the app, data transfer to the TeltoCare platform will not be available. | + | ||'''Please note:'''<br>To ensure uninterrupted data transfer from your watch to the platform, it is important to keep the TeltoHeart application running in the background at all times. If you close the app, data transfer to the TeltoCare platform will not be available. |
|} | |} | ||
|- | |- | ||
|} | |} | ||
+ | |||
+ | |||
==Recording an ECG== | ==Recording an ECG== | ||
{| class="tlt-border" style="border: 1px solid #e8e8e8; background: white; width: 100%;" | {| class="tlt-border" style="border: 1px solid #e8e8e8; background: white; width: 100%;" | ||
|- | |- | ||
− | |colspan="3" style="text-align: center; background: white; padding: 10px;"| '''Recording an ECG''' | + | | colspan="3" style="text-align: center; background: white; padding: 10px;" |'''Recording an ECG''' |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| '''Before you start''' | + | | colspan="3" style="text-align: left; padding: 10px;" |'''Before you start''' |
* To measure and record physiological parameters, TeltoHeart utilizes photoplethysmography (PPG) and electrocardiogram (ECG). | * To measure and record physiological parameters, TeltoHeart utilizes photoplethysmography (PPG) and electrocardiogram (ECG). | ||
* To transmit ECG data, ensure that TeltoHeart and TeltoHeart mobile application are paired with iOS 14 or later / Android 10 or later. | * To transmit ECG data, ensure that TeltoHeart and TeltoHeart mobile application are paired with iOS 14 or later / Android 10 or later. | ||
* To activate the ECG function, simply open the ECG function in TeltoHeart. | * To activate the ECG function, simply open the ECG function in TeltoHeart. | ||
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| '''Setup''' | + | | colspan="3" style="text-align: left; padding: 10px;" |'''Setup''' |
− | * Push the side button once to open up a menu. | + | *Push the side button once to open up a menu. |
− | * Tap the ECG function icon [[Image:ecg5.png|20px|link=]] on your TeltoHeart. | + | *Tap the ECG function icon [[Image:ecg5.png|20px|link=]] on your TeltoHeart. |
− | * Follow instructions on screen. | + | *Follow instructions on screen. |
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| '''How to take ECG recording''' | + | | colspan="3" style="text-align: left; padding: 10px;" |'''How to take ECG recording''' |
[[Image:Nr1.png|50px|link=]] Follow the instructions on screen and tap NEXT. | [[Image:Nr1.png|50px|link=]] Follow the instructions on screen and tap NEXT. | ||
<br> | <br> | ||
[[Image:Nr2.png|50px|link=]] Please sit down and make sure TeltoHeart is on your left wrist and strapped tightly but comfortably. | [[Image:Nr2.png|50px|link=]] Please sit down and make sure TeltoHeart is on your left wrist and strapped tightly but comfortably. | ||
{| align="center" | {| align="center" | ||
− | | [[Image:Wrist.png|300px|link=]] | + | |[[Image:Wrist.png|300px|link=]] |
− | | [[Image:ECG1.png|150px|link=]] | + | |[[Image:ECG1.png|150px|link=]] |
|} | |} | ||
[[Image:Nr3.png|50px|link=]] Place and hold the abdomen electrode on the left abdomen side in the level of the belly button. | [[Image:Nr3.png|50px|link=]] Place and hold the abdomen electrode on the left abdomen side in the level of the belly button. | ||
{| align="center" | {| align="center" | ||
− | | [[Image:ECG_measurement-2.png|300px|link=]] | + | |[[Image:ECG_measurement-2.png|300px|link=]] |
− | | [[Image:ECG2.png|150px|link=]] | + | |[[Image:ECG2.png|150px|link=]] |
|} | |} | ||
[[Image:Nr4.png|50px|link=]] While holding the abdomen electrode on the left abdomen side in the level of the belly button, put your right hand finger on the finger electrode above the screen. | [[Image:Nr4.png|50px|link=]] While holding the abdomen electrode on the left abdomen side in the level of the belly button, put your right hand finger on the finger electrode above the screen. | ||
{| align="center" | {| align="center" | ||
− | | [[Image:ECG_measurement-3.png|300px|link=]] | + | |[[Image:ECG_measurement-3.png|300px|link=]] |
− | | [[Image:ECG3.png|150px|link=]] | + | |[[Image:ECG3.png|150px|link=]] |
|} | |} | ||
[[Image:Nr5 - Copy.png|50px|link=]] Select '''Tap to Record''' and during the countdown, perform the actions described above. Do not forget to keep your right hand finger on the finger electrode and remain still during recording. | [[Image:Nr5 - Copy.png|50px|link=]] Select '''Tap to Record''' and during the countdown, perform the actions described above. Do not forget to keep your right hand finger on the finger electrode and remain still during recording. | ||
<br> | <br> | ||
{| align="center" | {| align="center" | ||
− | | [[Image:ECG4.png|150px|link=]] | + | |[[Image:ECG4.png|150px|link=]] |
|} | |} | ||
<br> | <br> | ||
Line 214: | Line 211: | ||
[[Image:Nr7.png|50px|link=]] Once the recording is finished, you will see the message Recording completed displayed on the TeltoHeart screen. | [[Image:Nr7.png|50px|link=]] Once the recording is finished, you will see the message Recording completed displayed on the TeltoHeart screen. | ||
|- | |- | ||
− | |colspan="3" style="text-align: left; padding: 10px;"| | + | | colspan="3" style="text-align: left; padding: 10px;" | |
{| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | {| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | ||
− | | style="width: 40px;height: 20px;padding: 10px;" | [[File:Note_icon.png|30 px|link=]] | + | | style="width: 40px;height: 20px;padding: 10px;" |[[File:Note_icon.png|30 px|link=]] |
− | || '''Please note:'''<br> | + | ||'''Please note:'''<br> |
− | * Please keep the TeltoHeart application running in the background to allow measurement data transfer. | + | *Please keep the TeltoHeart application running in the background to allow measurement data transfer. |
− | * ECG recordings cannot be performed if battery charge is less than 10%. | + | *ECG recordings cannot be performed if battery charge is less than 10%. |
|} | |} | ||
|} | |} | ||
− | ==How to view data in TeltoCare== | + | == How to view data in TeltoCare== |
{| class="tlt-border" style="border: 1px solid #e8e8e8;" | {| class="tlt-border" style="border: 1px solid #e8e8e8;" | ||
|- | |- | ||
− | | [[Image:Nr1.png|50px|link=]] Open a web browser and go to the URL [https://teltocare.com TeltoCare] | + | |[[Image:Nr1.png|50px|link=]] Open a web browser and go to the URL [https://teltocare.com TeltoCare] |
<br> | <br> | ||
[[Image:Nr2.png|50px|link=]] Enter your login details in the login field. | [[Image:Nr2.png|50px|link=]] Enter your login details in the login field. | ||
{| class="main-table" style="background: #E7F1FE; color: black;" | {| class="main-table" style="background: #E7F1FE; color: black;" | ||
+ | |} | ||
{| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | {| style="width: 800px;height: 60px; text-align: left; border: 1px solid #0054A6; border-bottom: 1px solid #0054A6; border-left: 1px solid #0054A6;border-top: 1px solid #0054A6;border-right: 1px solid #0054A6;background: #E7F1FE; color: black; text-align: left; padding: 10px;" | ||
− | | style="width: 40px;height: 20px;padding: 10px;" | [[File:Note_icon.png|30px|link=]] | + | | style="width: 40px;height: 20px;padding: 10px;" |[[File:Note_icon.png|30px|link=]] |
− | || '''Please note:'''<br> | + | ||'''Please note:'''<br> |
TeltoHeart mobile application and TeltoCare share the same login details. | TeltoHeart mobile application and TeltoCare share the same login details. | ||
|} | |} | ||
<br> | <br> | ||
{| align="center" | {| align="center" | ||
− | | [[Image:TeltoCare.png|300px|link=]] | + | |[[Image:TeltoCare.png|300px|link=]] |
|} | |} | ||
<br> | <br> | ||
Line 245: | Line 243: | ||
[[Image:Nr7.png|50px|link=]] If you do not see your ECG measurement data reflected in the TeltoCare platform yet, you have the option to perform a Force sync connection within the TeltoHeart application. This feature allows you to manually initiate a data transfer and ensure that your ECG data is sent to the TeltoCare platform. Although data is sent periodically, if there are any delays or missing data, utilizing the Force sync option in the TeltoHeart application enables you to trigger the data transfer process and ensure the availability of your ECG measurements in the TeltoCare platform.<br> | [[Image:Nr7.png|50px|link=]] If you do not see your ECG measurement data reflected in the TeltoCare platform yet, you have the option to perform a Force sync connection within the TeltoHeart application. This feature allows you to manually initiate a data transfer and ensure that your ECG data is sent to the TeltoCare platform. Although data is sent periodically, if there are any delays or missing data, utilizing the Force sync option in the TeltoHeart application enables you to trigger the data transfer process and ensure the availability of your ECG measurements in the TeltoCare platform.<br> | ||
{| align="center" | {| align="center" | ||
− | | [[Image:MyHealth-6.png|300px|link=]] | + | |[[Image:MyHealth-6.png|300px|link=]] |
|} | |} | ||
|} | |} | ||
− | ==How to power off or restart TeltoHeart== | + | == How to power off or restart TeltoHeart== |
− | {| cellspacing="0" cellpadding="0" width="100% | + | {| class="tlt-border" cellspacing="0" cellpadding="0" width="100%" style="width: 100%;border: 1px solid #e8e8e8;" ; |
|- | |- | ||
− | | [[Image:Nr1.png|50px|link=]] In the main screen, swipe up, locate and tap [[Image:Group_4225.png|30px|link=]] power icon | + | |[[Image:Nr1.png|50px|link=]] In the main screen, swipe up, locate and tap [[Image:Group_4225.png|30px|link=]] power icon |
{| align="center" | {| align="center" | ||
− | | [[Image:Group_1388.png|200px|link=]] | + | |[[Image:Group_1388.png|200px|link=]] |
|} | |} | ||
|- | |- | ||
− | | [[Image:Nr2.png|50px|link=]] Press and hold <b>Power off</b> button to turn off or <b>Restart</b> to restart the device. | + | |[[Image:Nr2.png|50px|link=]] Press and hold <b>Power off</b> button to turn off or <b>Restart</b> to restart the device. |
{| align="center" | {| align="center" | ||
− | | [[Image:Group_1337.png|200px|link=]] | + | |[[Image:Group_1337.png|200px|link=]] |
|} | |} | ||
|} | |} | ||
=Technical specifications= | =Technical specifications= | ||
{| class="tlt-border" style="border: 1px solid #e8e8e8;" | {| class="tlt-border" style="border: 1px solid #e8e8e8;" | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''BODY'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''BODY'''</span></p><hr> |
|- | |- | ||
|'''Dimensions (Width x Length x Height):''' | |'''Dimensions (Width x Length x Height):''' | ||
|40.5 (1.6") x 47 (1.9") x 14.7 (0.6") mm | |40.5 (1.6") x 47 (1.9") x 14.7 (0.6") mm | ||
|- | |- | ||
− | |'''Weight:''' | + | |'''Weight:''' |
|52 g | |52 g | ||
|- | |- | ||
− | |'''Main CPU: ''' | + | |'''Main CPU: ''' |
| | | | ||
− | *nRF5340 | + | *nRF5340 |
*2x ARM Cortex M33 cores for application and network | *2x ARM Cortex M33 cores for application and network | ||
|- | |- | ||
− | |'''Platform (OS):''' | + | |'''Platform (OS):''' |
− | |Zephyr RTOS | + | |Zephyr RTOS |
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''DISPLAY'''</span></p> <hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''DISPLAY'''</span></p> <hr> |
|- | |- | ||
|'''Brightness:''' | |'''Brightness:''' | ||
− | |250 NITS | + | | 250 NITS |
|- | |- | ||
− | |'''Resolution: ''' | + | |'''Resolution: ''' |
− | |240 x 240 px | + | | 240 x 240 px |
|- | |- | ||
− | |'''Type:''' | + | |'''Type:''' |
− | |LCD TFT | + | | LCD TFT |
|- | |- | ||
− | |'''Size:''' | + | |'''Size:''' |
|1.3“ | |1.3“ | ||
|- | |- | ||
− | |'''Cover lens:''' | + | |'''Cover lens:''' |
− | |Corning gorilla glass 3 | + | |Corning gorilla glass 3 |
|- | |- | ||
− | |'''Surface hardness:''' | + | |'''Surface hardness:''' |
|>8 H | |>8 H | ||
|- | |- | ||
− | |'''Display area:''' | + | |'''Display area:''' |
|547.56 sq mm | |547.56 sq mm | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''TELTOHEART MEMORY'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''TELTOHEART MEMORY'''</span></p><hr> |
|- | |- | ||
|'''Capacity:''' | |'''Capacity:''' | ||
− | |128 Mb | + | | 128 Mb |
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''CONNECTIVITY'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''CONNECTIVITY'''</span></p><hr> |
|- | |- | ||
− | |'''Bluetooth version:''' | + | |'''Bluetooth version:''' |
|5.3 | |5.3 | ||
|- | |- | ||
− | |'''Remote access:''' | + | |'''Remote access:''' |
− | |Cloud | + | |Cloud |
|- | |- | ||
| colspan="2" | | | colspan="2" | | ||
Line 324: | Line 322: | ||
|3 dBm | |3 dBm | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''FEATURES'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''FEATURES'''</span></p><hr> |
|- | |- | ||
| colspan="2" | | | colspan="2" | | ||
− | *ECG sensors for electrocardiogram | + | * ECG sensors for electrocardiogram |
− | *PPG sensors for AFib detection | + | * PPG sensors for AFib detection |
*Heart rate monitoring | *Heart rate monitoring | ||
Line 341: | Line 339: | ||
*Protection level against ingress of solid objects: IP 67 | *Protection level against ingress of solid objects: IP 67 | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''POWER SUPPLY'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''POWER SUPPLY'''</span></p><hr> |
|- | |- | ||
|'''Build-in rechargeable Li-Po battery (not replaceable by the user):''' | |'''Build-in rechargeable Li-Po battery (not replaceable by the user):''' | ||
| | | | ||
− | *410 mAh, | + | * 410 mAh, |
*1.56 Wh | *1.56 Wh | ||
|- | |- | ||
− | |'''Charging voltage: ''' | + | |'''Charging voltage: ''' |
|5 V ⎓ | |5 V ⎓ | ||
|- | |- | ||
− | |'''Operating voltage:''' | + | |'''Operating voltage:''' |
− | | | + | | |
*Internal Battery 3.8 V ⎓ | *Internal Battery 3.8 V ⎓ | ||
*External power supply 5 V ⎓ | *External power supply 5 V ⎓ | ||
|- | |- | ||
− | |'''Max. Input current (A):''' | + | |'''Max. Input current (A):''' |
− | |0.5 A | + | | 0.5 A |
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''SENSORS AND COMPONENTS'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''SENSORS AND COMPONENTS'''</span></p><hr> |
|- | |- | ||
| colspan="2" | | | colspan="2" | | ||
*Accelerometer | *Accelerometer | ||
− | *Gyroscope | + | *Gyroscope |
|- | |- | ||
| colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''BUTTONS'''</span></p><hr> | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''BUTTONS'''</span></p><hr> | ||
Line 369: | Line 367: | ||
| colspan="2" |Side button (Turn on, Restart, Back) | | colspan="2" |Side button (Turn on, Restart, Back) | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''STRAPS'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''STRAPS'''</span></p><hr> |
|- | |- | ||
− | | colspan="2" |The wristband with an electrode is made of silicone rubber with an integrated stainless-steel electrode | + | | colspan="2" | The wristband with an electrode is made of silicone rubber with an integrated stainless-steel electrode |
|- | |- | ||
− | |'''Strap material:''' | + | |'''Strap material:''' |
|Silicone | |Silicone | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''STRAP SIZE'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''STRAP SIZE'''</span></p><hr> |
|- | |- | ||
− | | | + | | |
− | *S | + | *S |
|- | |- | ||
| | | | ||
*M | *M | ||
|- | |- | ||
− | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''SUPPORTED PERIPHERALS'''</span></p><hr> | + | | colspan="2" |<br> <p style="font-size:28px"><span style="color:#0054A6">'''SUPPORTED PERIPHERALS'''</span></p><hr> |
|- | |- | ||
− | |'''ACCESSORIES:''' | + | |'''ACCESSORIES:''' |
| | | | ||
*TeltoHeart charging dock | *TeltoHeart charging dock | ||
Line 394: | Line 392: | ||
* Any CE marked wall charger with 5 V⎓/1A output and USB type-A connector | * Any CE marked wall charger with 5 V⎓/1A output and USB type-A connector | ||
− | *Any CE certified USB-A to USB-C cable | + | * Any CE certified USB-A to USB-C cable |
− | *Any smartphone operating on Android OS version 10 or above with Google play store service. | + | * Any smartphone operating on Android OS version 10 or above with Google play store service. |
− | *Any smartphone using iOS version 14 or above | + | * Any smartphone using iOS version 14 or above |
|- | |- | ||
| colspan="2" |<br> '''COMPATIBILITY WITH MRI OR CT WAS NOT CHECKED AND USE OF DEVICE IN MRI OR CT ENVIRONMENT IS PROHIBITED''' | | colspan="2" |<br> '''COMPATIBILITY WITH MRI OR CT WAS NOT CHECKED AND USE OF DEVICE IN MRI OR CT ENVIRONMENT IS PROHIBITED''' | ||
|- | |- | ||
− | |'''Bluetooth compatibility: ''' | + | |'''Bluetooth compatibility: ''' |
|Devices that use Bluetooth v5.0 or later in 2.4 GHz (2.402 – 2.480 GHz) band and SMP protocol are compatible with the device | |Devices that use Bluetooth v5.0 or later in 2.4 GHz (2.402 – 2.480 GHz) band and SMP protocol are compatible with the device | ||
|- | |- | ||
Line 410: | Line 408: | ||
* -10 to +45 ℃ | * -10 to +45 ℃ | ||
'''Charging temperature range:''' | '''Charging temperature range:''' | ||
− | * 0 to +45 ℃ | + | *0 to +45 ℃ |
'''Storage temperature range:''' | '''Storage temperature range:''' | ||
− | * 1 Month: -20 to +35 ℃ | + | *1 Month: -20 to +35 ℃ |
− | * 6 Months: -20 to +30 ℃ | + | *6 Months: -20 to +30 ℃ |
|- | |- | ||
|} | |} | ||
=Safety= | =Safety= | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <div style="font-size: 28px;display: flex; justify-content: center; align-items: center; height: 100%;"><h3><span style="color:#0054A6">Contraindications, Cautions, Warnings and Notes</span></h3></div> | + | |<div style="font-size: 28px;display: flex; justify-content: center; align-items: center; height: 100%;"><h3><span style="color:#0054A6">Contraindications, Cautions, Warnings and Notes</span></h3></div> |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | <span style="font-weight: normal;">'''CONTRAINDICATIONS'''</span> | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | |<span style="font-weight: normal;">'''CONTRAINDICATIONS'''</span> | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | <span style="font-weight: normal;">'''CAUTIONS'''</span> | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | |<span style="font-weight: normal;">'''CAUTIONS'''</span> | ||
|- | |- | ||
− | | <span style="font-weight: normal;">'''Handling and Care:'''</span> | + | |<span style="font-weight: normal;">'''Handling and Care:'''</span> |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Warranty and Claims:'''</span> | + | |<span style="font-weight: normal;">'''Warranty and Claims:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Any modifications, performed by third parties, will void the warranty. Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. | + | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | Any modifications, performed by third parties, will void the warranty. Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Connectivity and Data Management:'''</span> | + | |<span style="font-weight: normal;">'''Connectivity and Data Management:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |If data cannot be saved locally on your smartphone, please clear cache and try again. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |If data cannot be saved locally on your smartphone, please clear cache and try again. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |The device requires a stable internet connection to function properly. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | The device requires a stable internet connection to function properly. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Environmental and Safety Precautions:'''</span> | + | |<span style="font-weight: normal;">'''Environmental and Safety Precautions:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Avoid using TeltoHeart in sandy environments. Do not submerge the device in salty water or any other electrically conductive liquid. Do not use the device in MRI or CT environment. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Avoid using TeltoHeart in sandy environments. Do not submerge the device in salty water or any other electrically conductive liquid. Do not use the device in MRI or CT environment. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |TeltoHeart is not intended to be used underwater. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |TeltoHeart is not intended to be used underwater. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Storage:'''</span> | + | |<span style="font-weight: normal;">'''Storage:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Please store the docking station in an appropriate environment to avoid magnet degaussing. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Please store the docking station in an appropriate environment to avoid magnet degaussing. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Electromagnetic Fields and Ultrasound:'''</span> | + | |<span style="font-weight: normal;">'''Electromagnetic Fields and Ultrasound:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device in the presence of strong electromagnetic fields. | + | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device in the presence of strong electromagnetic fields. |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device near ultrasound equipment. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device near ultrasound equipment. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Cleaning and Maintenance:'''</span> | + | |<span style="font-weight: normal;">'''Cleaning and Maintenance:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Ensure that the magnetic connection of the docking station is clean of metallic bodies. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Ensure that the magnetic connection of the docking station is clean of metallic bodies. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Device Usage and Limitations:'''</span> | + | |<span style="font-weight: normal;">'''Device Usage and Limitations:'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |TeltoHeart is not supposed to be worn in situations where it would be exposed to strong vibrations, for example while working with rammer compactors, vibrating plate compactor machines, hammer drills, etc. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |TeltoHeart is not supposed to be worn in situations where it would be exposed to strong vibrations, for example while working with rammer compactors, vibrating plate compactor machines, hammer drills, etc. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Patients with diseases, which manifest as skin photosensitivity should not use the device. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not paint or put stickers on your device. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not paint or put stickers on your device. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not cause excessive mechanical strain or shock to the device. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not cause excessive mechanical strain or shock to the device. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |The device may be damaged, explode, or result in a fire if too much pressure is applied to it. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | The device may be damaged, explode, or result in a fire if too much pressure is applied to it. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |The device is not intended to be put in any bodily orifice. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | The device is not intended to be put in any bodily orifice. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |The device is meant to be used by adults of age 22 or older. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | The device is meant to be used by adults of age 22 or older. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Use on intact skin only. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | Use on intact skin only. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use excessive force while using the device. Excessive force may break or damage accessories. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use excessive force while using the device. Excessive force may break or damage accessories. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device in an environment where the temperature exceeds 45°C. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do not use the device in an environment where the temperature exceeds 45°C. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |The platform is not suitable for people with paralyzed, deformed arms, or absence of both arms. | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | The platform is not suitable for people with paralyzed, deformed arms, or absence of both arms. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |We strongly advise avoiding downloading or installing firmwares found in third party sites such as forums, etc. Installing unverified firmwares will result in warranty void. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |We strongly advise avoiding downloading or installing firmwares found in third party sites such as forums, etc. Installing unverified firmwares will result in warranty void. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Due to excess heat, the battery might be damaged. If the device starts heating, stop using the device immediately! | + | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Caution.png|80px|link=]] |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | Due to excess heat, the battery might be damaged. If the device starts heating, stop using the device immediately! | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''WARNINGS'''</span> | + | |<span style="font-weight: normal;">'''WARNINGS'''</span> |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''Battery safety:'''</span> | + | |<span style="font-weight: normal;">'''Battery safety:'''</span> |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |If the device starts heating, stop using it immediately to prevent damage to the battery and other components. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |If the device starts heating, stop using it immediately to prevent damage to the battery and other components. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT short-circuit the charging contacts. Exposing the contacts with a metallic object, such a coin, a clip or a set of keys can cause accidental short-circuiting and damage battery and other components. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT short-circuit the charging contacts. Exposing the contacts with a metallic object, such a coin, a clip or a set of keys can cause accidental short-circuiting and damage battery and other components. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | <span style="font-weight: normal;">'''Environmental safety:'''</span> | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | |<span style="font-weight: normal;">'''Environmental safety:'''</span> | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device outside of operational temperature conditions, for example in a sauna. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Do NOT use the device outside of operational temperature conditions, for example in a sauna. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | <span style="font-weight: normal;">'''User safety:'''</span> | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | |<span style="font-weight: normal;">'''User safety:'''</span> | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Comply with all safety warnings and regulations regarding mobile device usage while operating the vehicle. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |Comply with all safety warnings and regulations regarding mobile device usage while operating the vehicle. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:5%; vertical-align: middle; text-align: left;" |[[File:Warning.png|80px|link=]] | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |While driving, safely operating the vehicle is your first responsibility. Never use your mobile device while driving if it is prohibited by law. For your safety and the safety of others, use your common sense. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |While driving, safely operating the vehicle is your first responsibility. Never use your mobile device while driving if it is prohibited by law. For your safety and the safety of others, use your common sense. | ||
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | <span style="font-weight: normal;">'''NOTE'''</span> | + | |<span style="font-weight: normal;">'''NOTE'''</span> |
|- | |- | ||
|} | |} | ||
{| class="nd-othertables" style="width:100%;text-align: left;" | {| class="nd-othertables" style="width:100%;text-align: left;" | ||
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | '''Operating Temperature:''' | + | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Operating Temperature:''' |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | <span style="font-weight: normal;"> Device operating temperature is -10 to 45 degrees Celsius. | + | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |<span style="font-weight: normal;"> Device operating temperature is -10 to 45 degrees Celsius. |
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
+ | {| class="nd-othertables" style="width:100%;text-align: left;" | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Cleaning Instructions:''' | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Cleaning Instructions:''' | ||
|- | |- | ||
+ | |} | ||
{| class="nd-othertables" style="width:100%;text-align: left;" | {| class="nd-othertables" style="width:100%;text-align: left;" | ||
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | <span style="font-weight: normal;"> Please keep the device electrodes clean for best performance. | + | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |<span style="font-weight: normal;"> Please keep the device electrodes clean for best performance. |
|- | |- | ||
|} | |} | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Environmental:''' | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Environmental:''' | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
− | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" | | + | {| class="nd-othertables" style="width:100%;text-align: left;" |
+ | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |<span style="font-weight: normal;"> Usage in rain or in very humid environment is not recommended. | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
+ | {| class="nd-othertables" style="width:100%;text-align: left;" | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Account and Data:''' | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |'''Account and Data:''' | ||
|- | |- | ||
− | {|class="nd-othertables" style="width:100%;text-align: left;" | + | |} |
+ | {| class="nd-othertables" style="width:100%;text-align: left;" | ||
| rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |<span style="font-weight: normal;">TeltoHeart mobile application and TeltoCare share the same login details. | | rowspan="2" style="width:80%; vertical-align: middle; text-align: left;" |<span style="font-weight: normal;">TeltoHeart mobile application and TeltoCare share the same login details. | ||
|- | |- | ||
Line 643: | Line 675: | ||
=Equipment symbols= | =Equipment symbols= | ||
<div class="tlt-border" style="width: 98%; overflow: auto; padding-inline: 10px; border: 1px solid #e8e8e8;"> | <div class="tlt-border" style="width: 98%; overflow: auto; padding-inline: 10px; border: 1px solid #e8e8e8;"> | ||
− | {|cellspacing="0" cellpadding="0" width="100%" | + | {| cellspacing="0" cellpadding="0" width="100%" |
|+ | |+ | ||
!Symbol | !Symbol | ||
Line 653: | Line 685: | ||
|- | |- | ||
| [[image:Manufacturer.png|border|class=tlt-border|150px|link=]] | | [[image:Manufacturer.png|border|class=tlt-border|150px|link=]] | ||
− | | | + | | '''Manufacturer''' <br> TELTONIKA TELEMEDIC UAB<br> |
Ukmergės g. 120-1, LT-08126 Vilnius <br> | Ukmergės g. 120-1, LT-08126 Vilnius <br> | ||
[[/cdn-cgi/l/email-protection|[email protected]]] <br> | [[/cdn-cgi/l/email-protection|[email protected]]] <br> | ||
− | | + | https://www.teltonika-telemedic.com<br> |
| [[image:CE_Labeling_360x350_jpg.jpg|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_CE_RED]] | | [[image:CE_Labeling_360x350_jpg.jpg|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_CE_RED]] | ||
|- | |- | ||
| [[image:Consult_instructions_for_use.png|border|class=tlt-border|150px|link=]] | | [[image:Consult_instructions_for_use.png|border|class=tlt-border|150px|link=]] | ||
− | | Consult instructions for use | + | | Consult instructions for use |
| [[image:UKCA_labeling_360x350.png|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_UKCA]] | | [[image:UKCA_labeling_360x350.png|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_UKCA]] | ||
|- | |- | ||
| [[image:Temperature_limit.png|border|class=tlt-border|150px|link=]] | | [[image:Temperature_limit.png|border|class=tlt-border|150px|link=]] | ||
− | | Temperature limit | + | | Temperature limit |
| [[image:Fcc_logo.png|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_FCC]]<br> '''FCC ID:'''2BAIF-ECG200 | | [[image:Fcc_logo.png|border|class=tlt-border|150px|link=https://wiki.teltonika-telemedic.com/view/TeltoHeart_FCC]]<br> '''FCC ID:'''2BAIF-ECG200 | ||
|- | |- | ||
| [[image:IP67.png|border|class=tlt-border|150px|link=]] | | [[image:IP67.png|border|class=tlt-border|150px|link=]] | ||
− | | Protection against ingress of water or particulate matter | + | | Protection against ingress of water or particulate matter |
|- | |- | ||
| [[image:Weee_logo.png|border|class=tlt-border|150px|link=]]<br> | | [[image:Weee_logo.png|border|class=tlt-border|150px|link=]]<br> | ||
Line 680: | Line 712: | ||
Latest update changelog can be found on: [[TeltoHeart_firmware/software_changelogs| Update changelog]] | Latest update changelog can be found on: [[TeltoHeart_firmware/software_changelogs| Update changelog]] | ||
<div style="font-size: 16px;display: flex; align-items: center; height: 100%;"><h3><span style="color:#0054A6">TeltoCare manual</span></h3></div> | <div style="font-size: 16px;display: flex; align-items: center; height: 100%;"><h3><span style="color:#0054A6">TeltoCare manual</span></h3></div> | ||
− | Latest TeltoCare manual can be found on: [[ | + | Latest TeltoCare manual can be found on: [[ TeltoCare First Start]] |
<div style="font-size: 16px;display: flex; align-items: center; height: 100%;"><h3><span style="color:#0054A6">Documentation</span></h3></div> | <div style="font-size: 16px;display: flex; align-items: center; height: 100%;"><h3><span style="color:#0054A6">Documentation</span></h3></div> | ||
{| | {| | ||
Line 734: | Line 766: | ||
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |[[TeltoHeart UKCA|Yes]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |[[TeltoHeart UKCA|Yes]] | ||
|- | |- | ||
− | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |FCC (USA) | + | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" | FCC (USA) |
| style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |[[TeltoHeart FCC |Yes]] | | style="border: 1px solid white; border-bottom: 2px solid #E8E8E8; text-align: left; vertical-align: center; background: white;" |[[TeltoHeart FCC |Yes]] | ||
|} | |} |
Revision as of 11:13, 14 May 2024
Main Page > TeltoHeart > TeltoHeart First StartContents of the box
Charging dock used to charge TeltoHeart | TeltoHeart with strap attached | Instructions with easy-to-understand illustrations. | ||
|
How to wear TeltoHeart
Secure TeltoHeart around your left hand lower arm, 1 cm above your wrist bone, as illustrated. Avoid fastening it too tightly or too loosely. |
How to Charge TeltoHeart
Insert a USB Type-C cable into the charging dock. |
|||
To recharge, place TeltoHeart on the charging dock, which is included in the packaging. |
| ||
|
Overview
Overview |
Electrodes for ECG reading
Electrodes |
Start using TeltoHeart
Fill in the fields.
Click RegisterAfter registration, fill in login details in TeltoHeart mobile application to login.
How to Use TeltoHeart | ||||
To activate TeltoHeart, press and hold the button for not less than 10 seconds until the device screen powers on. | ||||
When TeltoHeart is turned on for the first time, it will prompt to download TeltoHeart application. | ||||
You will be able to locate TeltoHeart on the TeltoHeart application as its name will be displayed on the TeltoHeart screen. | ||||
Visit TeltoHeart to download the TeltoHeart application or scan the QR code below. Alternatively, you can explore the iOS app store or Google Play store and search for the TeltoHeart application made by Teltonika Telemedic. | ||||
| ||||
Scan the QR code to download the TeltoHeart application from the Apple Store |
Scan the QR code to download the TeltoHeart application from Google Play Store
| |||
After installing the app, tap icon to open the app. | ||||
Registration | ||||
---|---|---|---|---|
TeltoCare offers two registration options. | ||||
First option | ||||
Visit https://teltocare.com
Click Register | ||||
Second option | ||||
If it is your first time using the app, sign-in by entering your email address and the password, which has been sent to your email. Tap Log in to proceed. | ||||
TeltoHeart application will prompt you to change the default password to a personal preferred password of your choice. | ||||
Once you have successfully changed your password, the next step is to review and accept the Terms and Conditions. You will be prompted to acknowledge and agree to the Terms and Conditions and Privacy policy before proceeding. | ||||
Once signed-in, the TeltoHeart application will ask for Bluetooth permissions. Tap Allow to let the application use Bluetooth connection. | ||||
How to Pair TeltoHeart with TeltoHeart mobile application | ||||
Tap Pair device to proceed with the pairing process. | ||||
TeltoHeart application will initiate a search for nearby devices. | ||||
Select your smart wearable by tapping on it. | ||||
TeltoHeart will notify you of an incoming pair request. | ||||
When prompted to do so, enter the passkey shown on your TeltoHeart into the Bluetooth pairing request window in the TeltoHeart application. | ||||
TeltoHeart will notify you about a successful pair with the TeltoHeart application. | ||||
Make sure TeltoHeart application is always running in the background, otherwise the data transfer will not be available. | ||||
|
Recording an ECG
Recording an ECG | |||||||||
Before you start
| |||||||||
Setup
| |||||||||
How to take ECG recording
Follow the instructions on screen and tap NEXT.
Place and hold the abdomen electrode on the left abdomen side in the level of the belly button. While holding the abdomen electrode on the left abdomen side in the level of the belly button, put your right hand finger on the finger electrode above the screen. Select Tap to Record and during the countdown, perform the actions described above. Do not forget to keep your right hand finger on the finger electrode and remain still during recording.
| |||||||||
|
How to view data in TeltoCare
Open a web browser and go to the URL TeltoCare
|
How to power off or restart TeltoHeart
In the main screen, swipe up, locate and tap power icon
| |
Press and hold Power off button to turn off or Restart to restart the device.
|
Technical specifications
BODY | |
Dimensions (Width x Length x Height): | 40.5 (1.6") x 47 (1.9") x 14.7 (0.6") mm |
Weight: | 52 g |
Main CPU: |
|
Platform (OS): | Zephyr RTOS |
DISPLAY | |
Brightness: | 250 NITS |
Resolution: | 240 x 240 px |
Type: | LCD TFT |
Size: | 1.3“ |
Cover lens: | Corning gorilla glass 3 |
Surface hardness: | >8 H |
Display area: | 547.56 sq mm |
TELTOHEART MEMORY | |
Capacity: | 128 Mb |
CONNECTIVITY | |
Bluetooth version: | 5.3 |
Remote access: | Cloud |
Operating frequency: | 2402 MHz – 2480 MHz |
Max. output power: | 3 dBm |
FEATURES | |
| |
POWER SUPPLY | |
Build-in rechargeable Li-Po battery (not replaceable by the user): |
|
Charging voltage: | 5 V ⎓ |
Operating voltage: |
|
Max. Input current (A): | 0.5 A |
SENSORS AND COMPONENTS | |
| |
BUTTONS | |
Side button (Turn on, Restart, Back) | |
STRAPS | |
The wristband with an electrode is made of silicone rubber with an integrated stainless-steel electrode | |
Strap material: | Silicone |
STRAP SIZE | |
| |
| |
SUPPORTED PERIPHERALS | |
ACCESSORIES: |
|
Compatibility with other manufacturer accessories: |
|
COMPATIBILITY WITH MRI OR CT WAS NOT CHECKED AND USE OF DEVICE IN MRI OR CT ENVIRONMENT IS PROHIBITED | |
Bluetooth compatibility: | Devices that use Bluetooth v5.0 or later in 2.4 GHz (2.402 – 2.480 GHz) band and SMP protocol are compatible with the device |
CONDITIONS FOR USE | |
Temperature range Operation:
Charging temperature range:
Storage temperature range:
|
Safety
Contraindications, Cautions, Warnings and Notes |
CONTRAINDICATIONS |
Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". |
Patients with diseases, which manifest as skin photosensitivity should not use the device. |
CAUTIONS |
Handling and Care: |
Do NOT use the device on wounds as this may cause infection and pain. Threat the wounds first". |
Patients with diseases, which manifest as skin photosensitivity should not use the device. |
Warranty and Claims: |
Any modifications, performed by third parties, will void the warranty. Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. |
Warranty claims may be excluded if you do not use and maintain the device as instructed or if you repair or modify the device yourself. |
Connectivity and Data Management: |
If data cannot be saved locally on your smartphone, please clear cache and try again. |
The device requires a stable internet connection to function properly. |
Environmental and Safety Precautions: |
Avoid using TeltoHeart in sandy environments. Do not submerge the device in salty water or any other electrically conductive liquid. Do not use the device in MRI or CT environment. |
TeltoHeart is not intended to be used underwater. |
Storage: |
Please store the docking station in an appropriate environment to avoid magnet degaussing. |
Electromagnetic Fields and Ultrasound: |
Do not use the device in the presence of strong electromagnetic fields. |
Do not use the device near ultrasound equipment. |
Cleaning and Maintenance: |
Ensure that the magnetic connection of the docking station is clean of metallic bodies. |
Device Usage and Limitations: |
TeltoHeart is not supposed to be worn in situations where it would be exposed to strong vibrations, for example while working with rammer compactors, vibrating plate compactor machines, hammer drills, etc. |
Patients with diseases, which manifest as skin photosensitivity should not use the device. |
Do not paint or put stickers on your device. |
Do not cause excessive mechanical strain or shock to the device. |
The device may be damaged, explode, or result in a fire if too much pressure is applied to it. |
The device is not intended to be put in any bodily orifice. |
The device is meant to be used by adults of age 22 or older. |
Use on intact skin only. |
Do not use excessive force while using the device. Excessive force may break or damage accessories. |
Do not use the device in an environment where the temperature exceeds 45°C. |
The platform is not suitable for people with paralyzed, deformed arms, or absence of both arms. |
We strongly advise avoiding downloading or installing firmwares found in third party sites such as forums, etc. Installing unverified firmwares will result in warranty void. |
Due to excess heat, the battery might be damaged. If the device starts heating, stop using the device immediately! |
WARNINGS |
Battery safety: |
If the device starts heating, stop using it immediately to prevent damage to the battery and other components. |
Do NOT short-circuit the charging contacts. Exposing the contacts with a metallic object, such a coin, a clip or a set of keys can cause accidental short-circuiting and damage battery and other components. |
Environmental safety: |
Do NOT use the device outside of operational temperature conditions, for example in a sauna. |
User safety: |
Comply with all safety warnings and regulations regarding mobile device usage while operating the vehicle. |
While driving, safely operating the vehicle is your first responsibility. Never use your mobile device while driving if it is prohibited by law. For your safety and the safety of others, use your common sense. |
NOTE |
Operating Temperature: |
Device operating temperature is -10 to 45 degrees Celsius. |
Cleaning Instructions: |
Please keep the device electrodes clean for best performance. |
Environmental: |
Usage in rain or in very humid environment is not recommended. |
Account and Data: |
TeltoHeart mobile application and TeltoCare share the same login details. |
Warranty
The warranty conditions and term of warranty shall apply in accordance with agreed conditions between you and your supplier.
It is important to carefully read and follow information for user (included but not limited quick start guide, technical specifications and user manual) and terms and conditions provided by the manufacturer. Failure to adhere to these guidelines may result in malfunctions or damage to the product, for which the manufacturer cannot be held responsible. It is the responsibility of the user to ensure that they fully understand and comply with the information provided by the manufacturer and terms and conditions before using the product. By doing so, users can help ensure the safe and effective use of the product and avoid any potential damage or liability.
Equipment symbols
Symbol
|
Description
|
Certificates
|
---|---|---|
Manufacturer TELTONIKA TELEMEDIC UAB Ukmergės g. 120-1, LT-08126 Vilnius |
||
Consult instructions for use | ||
Temperature limit | FCC ID:2BAIF-ECG200 | |
Protection against ingress of water or particulate matter | ||
|
Additional information
Product page
https://teltonika-telemedic.com/products/teltoheart
Update changelog
Latest update changelog can be found on: Update changelog
TeltoCare manual
Latest TeltoCare manual can be found on: TeltoCare First Start
Documentation
TeltoHeart Quick Manual (EN) | (Updated on: 2024-02-09) | |
TeltoHeart Quick Manual (LT) | (Updated on: 2024-02-09) | |
TeltoHeart flyer short version (EN) | (Updated on: 2024-02-07) | |
TeltoHeart flyer long version (EN) | (Updated on: 2024-02-07) |
TeltoHeart mobile application
- TeltoHeart is not turning on
- TeltoHeart is not sending data
- Shows incorrect time or date
- Heart Rate signal missing
- Failed to detect wrist
- Paired device prior to registering/logging in
- TeltoHeart Connection lost
- Failed to pair the device
- Cannot see my data
- Incorrect ECG data
- Forgot password for TeltoHeart mobile application or TeltoCare platform
- No Atrial fibrillation data
Promotional material
TeltoHeart Promotional material
Certificates
Certificates | Links |
---|---|
CE/RED (EU) | Yes |
UKCA (UK) | Yes |
FCC (USA) | Yes |